Category
Negative Control
Long description
Negative control for Immunofluorescence staining with FITC and PE of mouse monoclonal antibodies. Assessment of non-specific binding of mouse monoclonal antibodies to human cell surface antigens.
Antibody come from
n/a
Other description
Provided as sterile filtered solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein. Protein A/G Chromatography
Clone
not specified
Antigen-antibody binding interaction
Mouse IgG1 antibody conjugated to FITC - IgG2a antibody conjugated to PE - Negative Control
Antibody is raised in
Mouse
Antibody's reacts with
see techfile
Antibody's reacts with these species
This antibody doesn't cross react with other species
Antibody's specificity
No Data Available
Application
Flow Cytometry
Antibody's suited for
Consult the appropriate fact sheet to determine the amount of antibody to be used as a control for PBMC or Whole Blood. PBMC: Gently add10 µl of MAB/10^6 PBMC in100 µl PBS. Mix gently and incubate for 15 minutes at 2¼ to 8¼ C. Wash twice with PBS and analyze. WHOLE BLOOD: Add 10 µl of MAB/100 µl of Whole Blood. Mix gently and incubate for 15 minutes at room temperature 20¼C. Lyse the whole blood. Wash once with PBS and analyze. See instrument manufacturerÕs instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope.
Storage
4ºC
Relevant references
no information yet
Protein number
see ncbi
Warnings
This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals. This datasheet is as accurate as reasonably achievable, but Nordic-MUbio accepts no liability for any inaccuracies or omissions in this information.
Properties
If you buy Antibodies supplied by nordc they should be stored frozen at - 24°C for long term storage and for short term at + 5°C.This nordc Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. nordc FITC is highly sensitive to pH extremes.
Description
Isotype or positive controls by peptides, antibodies and deactivated samples.Negative control peptides or isotypes available of the different species.
Conjugation
Anti-FITC Antibody
Additional isotype
IgG1,IgG2a
French translation
anticorps